Automatic station for isolation of nucleic acids Nexor 32
Пропускна здатність: 1–32 од. Об’єм зразка: 10–1000 мкл Відновлення: >95% Планшет: 96-лунковий …
Streamline® Class II biological safety cabinets provide optimal performance, now enhanced by the latest SentinelTM Silver microcontroller. The best-in-class ISOCIDETM powder coating suppresses microorganism growth and ensures cabinet cleanliness. With a new design and compliance with EN 12469 standards, the new Streamline® Class II biological safety cabinet exceeds standard safety criteria.
|
External dimensions (W x D x H), mm |
1340 x 810 x 1400 | |
| Internal working zone dimensions (W x D x H), mm | 1220 x 580 x 670 | |
| Average airflow velocity, m/s | Inflow | 0.45 |
| Downflow | 0.3 | |
| Efficiency of exhaust HEPA filter | 99.99% for particles of size 0.3 µm | |
| Efficiency of ULPA filter for downflow air | 99.999% for particles sized from 0.1 to 0.3 µm | |
| Sound level according to IESTRP-CC002.2*, dB, EN 12469 | 60 | |
| Fluorescent lamp intensity at zero ambient intensity, lux | 1118 | |
| Cabinet construction | Main body | 1.2 mm electro-galvanized steel 18 with a finished epoxy resin powder coating |
| Working zone |
1.2 mm stainless steel grade 304 |
|
| Nominal power, W | 360 | |
| Weight, kg | 230 | |
| Shipping weight, kg | 285 | |


Air intake occurs through openings located at the front edge of the work surface beneath the working zone and behind the rear wall. Incoming air and clean air do not mix.
External air creates a protective barrier, and the possibility of mixing the external air and clean air flows in the working zone is excluded. Cross-contamination between objects in different corners of the working zone is eliminated.
Closer to the work surface, the airflow is divided into front and rear flows. The front flow passes through the front air intake grille and further under the work surface, while the rear flow exits the working zone area through the rear wall air intake grille of the cabinet. A portion of the downflow air passes at high speed through the side air intake grilles of the work surface.
The air collected above the working zone is distributed as follows. 35% of the total air volume passes through the ULPA filter at the outlet and is released into the environment. 65% of the air passes through another ULPA filter (ULPA filter at the inlet) and returns to the working zone.


An alternative name for a biological safety cabinet is a biological safety cabinet, laminar biological safety box (not to be confused with a regular laminar box).
Пропускна здатність: 1–32 од. Об’єм зразка: 10–1000 мкл Відновлення: >95% Планшет: 96-лунковий …